4L4022 LITE Liner Silikon SkinTex 3 L SOFT Locking

Item number: 4L4022

Category: All products

Size

Amputation level: BK
Connector: Locking
Fabric Type: SkinTex without seam
Liner Thickness: 3 mm
Liner Profile: Uniform
Material Liner: Silicone Gel
Matrix: with outside matrix
Mobility grade: mobility class: 1-3

There are variations of this item. Please select the variation you wish.

Description

4L4022 LITE Liner Silikon SkinTex 3 L SOFT Locking

Mobility class: 1-3
for BK stumps
Connector: Locking (with distal connector)

Properties:

  • made from medical grade* silicone gel
  • seamless fabric cover
  • length approx. 43 cm
  • integrated outside matrix

 

  • standard with approx. 10 cm matrix
  • high comfort by using approx. 2,5 mm ComfortSil Silicone Gel
  • perfect pressure distribution
  • textile fabric for easy donning
  • reduced pistoning by the matrix
  • suitable for nearly all locking devices

 

Article number gray 4 cm distal
circumference
20 cm distal
circumference
40 cm distal
circumference
wight
in kg
4L4022-10-18-G 18 - 20,5 cm 23 - 30 cm 27 - 38 cm 0,49
4L4022-10-20-G 20 - 21,5 cm 24 - 32 cm 28 - 40 cm 0,52
4L4022-10-21-G 21 - 22,5 cm 26 - 32 cm 30 - 42 cm 0,54
4L4022-10-22-G 22 - 24 cm 27,5 - 34 cm 31 - 43 cm 0,57
4L4022-10-23,5-G 23,5 - 25,5 cm 29 - 35 cm 32 - 44 cm 0,60
4L4022-10-25-G 25 - 27,5 cm 3 - 36 cm 34 - 45 cm 0,63
4L4022-10-26,5-G 26,5 - 29,5 cm 31,5 - 38 cm 36 - 46 cm 0,69
4L4022-10-28-G 28 - 31,5 cm 33 - 40 cm 38 - 48 cm 0,73
4L4022-10-30-G 30 - 33,5 cm 35 - 42 cm 40 - 52 cm 0,78
4L4022-10-32-G 32 - 35,5 cm 37,5 - 44 cm 42 - 56 cm 0,83
4L4022-10-34-G 34 - 37,5 cm 40 - 46 cm 44 - 60 cm 0,88
4L4022-10-36-G 36 - 39,5 cm 42 - 48 cm 46 - 62 cm 0,91
4L4022-10-38-G 38 - 41,5 cm 44 - 52 cm 48 - 64 cm 0,97
4L4022-10-40-G 40 - 44,5 cm 46 - 54 cm 50 - 66 cm 1,00
4L4022-10-42-G 42 - 50 cm 47 - 55 cm 53 - 68 cm 1,10

 

 How to choose the correct liner size
a) Measure the circumference of the residual limb at 4 cm from the distal end.
b) Choose the liner size corresponding to this measurement or the next smaller size, respectively.
c) Do not choose a liner whose size exceeds the measurement taken.
d) Never reduce by more than one liner size in order to avoid unnecessarily high compression.


Important:
In locking liners, a matrix with 10 cm length is integrated as a standard.This matrix should end below the head of the fibula and must not exceed it, as this could result in problems during knee flexion.

Sizing

 How to choose the correct liner size
a) Measure the circumference of the residual limb at 4 cm from the distal end.
b) Choose the liner size corresponding to this measurement or the next smaller size, respectively.
c) Do not choose a liner whose size exceeds the measurement taken.
d) Never reduce by more than one liner size in order to avoid unnecessarily high compression.


Important:
In locking liners, a matrix with 10 cm length is integrated as a standard.This matrix should end below the head of the fibula and must not exceed it, as this could result in problems during knee flexion.