4W4022 LITE Liner Silikon SkinTex 2 SOFT Locking
Description
4W4022 LITE Liner Silikon SkinTex 2 SOFT Locking
Mobility class: 1-3
for BK stumps
Connector: Locking (with distal connector)
Properties:
- made from medical grade* silicone gel
-
seamless fabric cover
- standard with approx. 10 cm matrix
- high comfort by using approx. 2,5 mm ComfortSil Silicone Gel
- high adhesion between liner and skin
- perfect pressure distribution
- textile fabric for easy donning
- reduced pistoning by the matrix
- suitable for nearly all locking devices
| Article number | Matrix length | Distal Circumference |
| 4W4022-10-18 | approx. 10 cm | 18 cm |
| 4W4022-10-20 | approx. 10 cm | 20 cm |
| 4W4022-10-21 | approx. 10 cm | 21 cm |
| 4W4022-10-22 | approx. 10 cm | 22 cm |
| 4W4022-10-23,5 | approx. 10 cm | 23,5 cm |
| 4W4022-10-25 | approx. 10 cm | 25 cm |
| 4W4022-10-26,5 | approx. 10 cm | 26,5 cm |
| 4W4022-10-28 | approx. 10 cm | 28 cm |
| 4W4022-10-30 | approx. 10 cm | 30 cm |
| 4W4022-10-32 | approx. 10 cm | 32 cm |
| 4W4022-10-34 | approx. 10 cm | 34 cm |
| 4W4022-10-36 |
approx. 10 cm |
36 cm |
| 4W4022-10-38 | approx. 10 cm | 38 cm |
| 4W4022-10-40 | approx. 10 cm | 40 cm |
| 4W4022-10-42 | approx. 10 cm | 42 cm |
| 4W4022-10-45 | approx. 10 cm | 45 cm |
| 4W4022-10-50 | approx. 10 cm | 50 cm |
| 4W4022-10-55 | approx. 10 cm | 55 cm |
Remark: Standard with matrix length of 10 cm, the matrix lengths 0 cm, 5 cm as well as 15 cm are available as well.
Remark:: The silicones used have been tested for biocompatibility according to DIN EN ISO 10993-5.
Matrix lengths
| Article No. | Matrix length | Distal Circiumference |
| 4W4022-00-18 | no Matrix | 18 cm |
| 4W4022-00-20 | no Matrix | 20 cm |
| 4W4022-00-21 | no Matrix | 21 cm |
| 4W4022-00-22 | no Matrix | 22 cm |
| 4W4022-00-23,5 | no Matrix | 23,5 cm |
| 4W4022-00-25 | no Matrix | 25 cm |
| 4W4022-00-26,5 | no Matrix | 26,5 cm |
| 4W4022-00-28 | no Matrix | 28 cm |
| 4W4022-00-30 | no Matrix | 30 cm |
| 4W4022-00-32 | no Matrix | 32 cm |
| 4W4022-00-34 | no Matrix | 34 cm |
| 4W4022-00-36 | no Matrix | 36 cm |
| 4W4022-00-38 | no Matrix | 38 cm |
| 4W4022-00-40 | no Matrix | 40 cm |
| 4W4022-00-42 | no Matrix | 42 cm |
| 4W4022-00-45 | no Matrix | 45 cm |
| 4W4022-00-50 | no Matrix | 50 cm |
| 4W4022-00-55 | no Matrix | 55 cm |
Matrix length: 5 cm
| Article No. | Matrix length | Distal Circiumference |
| 4W4022-05-18 | approx. 5 cm | 18 cm |
| 4W4022-05-20 | approx. 5 cm | 20 cm |
| 4W4022-05-21 | approx. 5 cm | 21 cm |
| 4W4022-05-22 | approx. 5 cm | 22 cm |
| 4W4022-05-23,5 | approx. 5 cm | 23,5 cm |
| 4W4022-05-25 | approx. 5 cm | 25 cm |
| 4W4022-05-26,5 | approx. 5 cm | 26,5 cm |
| 4W4022-05-28 | approx. 5 cm | 28 cm |
| 4W4022-05-30 | approx. 5 cm | 30 cm |
| 4W4022-05-32 | approx. 5 cm | 32 cm |
| 4W4022-05-34 | approx. 5 cm | 34 cm |
| 4W4022-05-36 | approx. 5 cm | 36 cm |
| 4W4022-05-38 | approx. 5 cm | 38 cm |
| 4W4022-05-40 | approx. 5 cm | 40 cm |
| 4W4022-05-42 | approx. 5 cm | 42 cm |
| 4W4022-05-45 | approx. 5 cm | 45 cm |
| 4W4022-05-50 | approx. 5 cm | 50 cm |
| 4W4022-05-55 | approx. 5 cm | 55 cm |
Matrix length: 15 cm
| Article No. | Matrix length | Distal Circiumference |
| 4W4022-15-18 | approx. 15 cm | 18 cm |
| 4W4022-15-20 | approx. 15 cm | 20 cm |
| 4W4022-15-21 | approx. 15 cm | 21 cm |
| 4W4022-15-22 | approx. 15 cm | 22 cm |
| 4W4022-15-23,5 | approx. 15 cm | 23,5 cm |
| 4W4022-15-25 | approx. 15 cm | 25 cm |
| 4W4022-15-26,5 | approx. 15 cm | 26,5 cm |
| 4W4022-15-28 | approx. 15 cm | 28 cm |
| 4W4022-15-30 | approx. 15 cm | 30 cm |
| 4W4022-15-32 | approx. 15 cm | 32 cm |
| 4W4022-15-34 | approx. 15 cm | 34 cm |
| 4W4022-15-36 | approx. 15 cm | 36 cm |
| 4W4022-15-38 | approx. 15 cm | 38 cm |
| 4W4022-15-40 | approx. 15 cm | 40 cm |
| 4W4022-15-42 | approx. 15 cm | 42 cm |
| 4W4022-15-45 | approx. 15 cm | 45 cm |
| 4W4022-15-50 | approx. 15 cm | 50 cm |
| 4W4022-15-55 | approx. 15 cm | 55 cm |
Sizing
Selecting the correct liner size
a) Measure the residual-limb circumference 4 cm above the distal end.
b) Choose the liner size that matches this measurement, or the next smaller size.
c) Do not select a liner size larger than the measured circumference.
d) Never reduce by more than one liner size to avoid unnecessarily high compression.

Important!
In a liner with connector, a matrix with approx. 10 cm length is integrated as standard. This matrix must end distal to the fibular head and must not extend beyond it, otherwise problems with knee flexion may occur.