4W4062 LITE Liner Silikon SkinTex 6 SOFT Locking

Item number: 4W4062

Category: W-Liner

Matrix
size

Amputation level: BK
Connector: Locking
Fabric Type: SkinTex without seam
Liner Thickness: 6 mm
Liner Profile: Uniform
Material Liner: Silicone Gel
Mobility grade: mobility class: 1-3
Matrix: without matrix with inner matrix

There are variations of this item. Please select the variation you wish.

Description

4W4062 LITE Liner Silikon SkinTex 6 SOFT Locking

Mobility class: 1-3
for BK stumps
Connector: Locking (with distal connector)

Properties:

  • made from medical grade* ComfortSil Silicone Gel
  • seamless fabric cover
     
  • standard with approx. 10 cm matrix
  • high comfort by using approx. 6 mm ComfortSil Silicone Gel. As a result, the liner is ideal for stumps with pressure sensitivities by prominent bony areas.
  • high adhesion between liner and skin
  • perfect pressure distribution
  • textile fabric for easy donning
  • reduced pistoning by the matrix
  • suitable for nearly all locking devices

 

Article No. distal Circumference
4W4062-10-20 20 cm
4W4062-10-21 21 cm
4W4062-10-22 22 cm
4W4062-10-23,5 23,5 cm
4W4062-10-25 25 cm
4W4062-10-26,5 26,5 cm
4W4062-10-28 28 cm
4W4062-10-30 30 cm
4W4062-10-32 32 cm
4W4062-10-34 34 cm
4W4062-10-36 36 cm
4W4062-10-38 38 cm
4W4062-10-40 40 cm
4W4062-10-42 42 cm
4W4062-10-45 45 cm

Matrix lengths

Matrix length: 0 cm

Article No. Matrix length Distal Circiumference
4W4062-00-16  no Matrix 16 cm
4W4062-00-18  no Matrix 18 cm
4W4062-00-20  no Matrix 20 cm
4W4062-00-21  no Matrix  21 cm
4W4062-00-22  no Matrix 22 cm
4W4062-00-23,5  no Matrix 23,5 cm
4W4062-00-25  no Matrix 25 cm
4W4062-00-26,5  no Matrix  26,5 cm
4W4062-00-28  no Matrix 28 cm
4W4062-00-30  no Matrix 30 cm
4W4062-00-32  no Matrix 32 cm
4W4062-00-34  no Matrix 34 cm
4W4062-00-36  no Matrix 36 cm
4W4062-00-38  no Matrix 38 cm
4W4062-00-40  no Matrix 40 cm
4W4062-00-42  no Matrix 42 cm
4W4062-00-45  no Matrix 45 cm

Sizing

 How to choose the correct liner size
a) Measure the circumference of the residual limb at 4 cm from the distal end.
b) Choose the liner size corresponding to this measurement or the next smaller size, respectively.
c) Do not choose a liner whose size exceeds the measurement taken.
d) Never reduce by more than one liner size in order to avoid unnecessarily high compression.

Important:
In locking liners, a matrix with 10 cm length is integrated as a standard.This matrix should end below the head of the fibula and must not exceed it, as this could result in problems during knee flexion.