4W4021 LITE Liner Silikon SkinTex 2 Locking

Item number: 4W4021

Category: All products

Matrix
size

Amputation level: BK
Connector: Locking
Fabric Type: SkinTex without seam
Liner Thickness: 3 mm
Liner Profile: Uniform
Material Liner: Silicone
Matrix: without matrix with inner matrix
Mobility grade: mobility class: 2-4

There are variations of this item. Please select the variation you wish.

Description

4W4021 LITE Liner Silikon SkinTex 2 Locking

Mobility class: 2-4
for BK stumps
Connector: Locking (with distal connector)

Properties:

  • made from medical grade* silicone
  • seamless fabric cover
     
  • Standard with 10 cm Matrix
  • stability by using 2,5 mm DuraSil
  • high adhesion between liner and skin
  • perfect pressure distribution
  • reduced pistoning by the matrix
  • suitable for nearly all locking devices

Article-No. 

Matrix length  Distal Circumference
4W4021-10-16 approx. 10 cm 16 cm
4W4021-10-18 approx. 10 cm 18 cm
4W4021-10-20  approx. 10 cm  20 cm
4W4021-10-21  approx. 10 cm  21 cm
4W4021-10-22  approx. 10 cm  22 cm
4W4021-10-23,5  approx. 10 cm  23,5 cm
4W4021-10-25  approx. 10 cm  25 cm
4W4021-10-26,5  approx. 10 cm  26,5 cm
4W4021-10-28  approx. 10 cm  28 cm
4W4021-10-30  approx. 10 cm  30 cm
4W4021-10-32  approx. 10 cm  32 cm
4W4021-10-34  approx. 10 cm  34 cm
4W4021-10-36  approx. 10 cm  36 cm
4W4021-10-38  approx. 10 cm  38 cm
4W4021-10-40  approx. 10 cm  40 cm
4W4021-10-42  approx. 10 cm  42 cm
4W4021-10-45  approx. 10 cm  45 cm
4W4021-10-50 approx. 10 cm 50 cm
4W4021-10-55 approx. 10 cm 55 cm

Also available with seam as 4W2021 -...

Matrix lengths

Matrix length: 0 cm

Article No. Matrix length Distal Circiumference
4W4021-00-16  no Matrix 16 cm
4W4021-00-18  no Matrix 18 cm
4W4021-00-20  no Matrix 20 cm
4W4021-00-21  no Matrix  21 cm
4W4021-00-22  no Matrix 22 cm
4W4021-00-23,5  no Matrix 23,5 cm
4W4021-00-25  no Matrix 25 cm
4W4021-00-26,5  no Matrix  26,5 cm
4W4021-00-28  no Matrix 28 cm
4W4021-00-30  no Matrix 30 cm
4W4021-00-32  no Matrix 32 cm
4W4021-00-34  no Matrix 34 cm
4W4021-00-36  no Matrix 36 cm
4W4021-00-38  no Matrix 38 cm
4W4021-00-40  no Matrix 40 cm
4W4021-00-42  no Matrix 42 cm
4W4021-00-45  no Matrix 45 cm

Matrix length: 5 cm



Article No. Matrix length Distal Circiumference
4W4021-05-16  approx. 5 cm  16 cm
4W4021-05-18  approx. 5 cm  18 cm
4W4021-05-20  approx. 5 cm  20 cm
4W4021-05-21  approx. 5 cm  21 cm
4W4021-05-22  approx. 5 cm  22 cm
4W4021-05-23,5  approx. 5 cm  23,5 cm
4W4021-05-25  approx. 5 cm  25 cm
4W4021-05-26,5  approx. 5 cm  26,5 cm
4W4021-05-28  approx. 5 cm  28 cm
4W4021-05-30  approx. 5 cm  30 cm
4W4021-05-32  approx. 5 cm  32 cm
4W4021-05-34  approx. 5 cm  34 cm
4W4021-05-36  approx. 5 cm  36 cm
4W4021-05-38  approx. 5 cm  38 cm
4W4021-05-40  approx. 5 cm  40 cm
4W4021-05-42  approx. 5 cm  42 cm
4W4021-05-45  approx. 5 cm  45 cm

Matrix length: 15 cm


Article No. Matrix length Distal Circiumference
4W4021-15-16  approx. 15 cm  16 cm
4W4021-15-18  approx. 15 cm  18 cm
4W4021-15-20  approx. 15 cm  20 cm
4W4021-15-21  approx. 15 cm  21 cm
4W4021-15-22  approx. 15 cm  22 cm
4W4021-15-23,5  approx. 15 cm  23,5 cm
4W4021-15-25  approx. 15 cm  25 cm
4W4021-15-26,5  approx. 15 cm  26,5 cm
4W4021-15-28  approx. 15 cm  28 cm
4W4021-15-30  approx. 15 cm  30 cm
4W4021-15-32  approx. 15 cm  32 cm
4W4021-15-34  approx. 15 cm  34 cm
4W4021-15-36  approx. 15 cm  36 cm
4W4021-15-38  approx. 15 cm  38 cm
4W4021-15-40  approx. 15 cm  40 cm
4W4021-15-42  approx. 15 cm  42 cm
4W4021-15-45  approx. 15 cm  45 cm

Sizing

 How to choose the correct liner size
a) Measure the circumference of the residual limb at 4 cm from the distal end.
b) Choose the liner size corresponding to this measurement or the next smaller size, respectively.
c) Do not choose a liner whose size exceeds the measurement taken.
d) Never reduce by more than one liner size in order to avoid unnecessarily high compression.

Important:
In locking liners, a matrix with 10 cm length is integrated as a standard.This matrix should end below the head of the fibula and must not exceed it, as this could result in problems during knee flexion.